Sma SC 500CP XT Installation User Manual Page 52

  • Download
  • Add to my manuals
  • Print
  • Page
    / 82
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 51
8 Technical Data
8.1 SunnyCentral500CPXT
DC Input
Maximum DC Power 560kW
Minimum input voltage / maximum input voltage 400Vto1,000V
Minimum MPP voltage 430V
MPP voltage range at +25C 449Vto850V
MPP voltage range at +50C 430Vto850V
MPP voltage range at +25°C and 60Hz 449Vto850V
MPP voltage range at +50°C and 60Hz 436Vto850V
Rated input voltage 449V
Maximum input current 1,250A
Maximum short-circuit current 2,500 A
Maximum reverse current 2,300 A
Number of independent MPP inputs 1
Number of DC inputs 9
AC Output
Rated power at +25°C 550kVA
Rated power at +50°C 500kVA
Nominal AC voltage 270V
Nominal AC voltage range 243Vto310V
AC power frequency 50Hz/60Hz
AC power frequency range 47Hzto63Hz
Rated frequency 50Hz
Rated grid voltage 270V
Maximum total harmonic distortion 0.03
Maximum AC current 1,176A
1,238A*
Maximum overcurrent protection at output 50,000 A
Maximum residual current at the AC output 3,500 A
Power factor at rated power 1
Displacement power factor cosφ 0.9overexcitedto0.9underexcited
8 Technical Data
SMA Solar Technology AG
Operating ManualSCCPXT-IA-E4-en-4452
Page view 51
1 2 ... 47 48 49 50 51 52 53 54 55 56 57 ... 81 82

Comments to this Manuals

No comments