Page view 52
Additional grounding 6.0Nm
SUNCLIX swivel nut 2.0Nm
RS485 communication or Speedwire/Webcon-
nect connection
1.5Nm
Multifunction relay connection 1.5Nm
11.7 ElectronicSolarSwitch
Electrical endurance in the event of short circuit,
at nominal current of 35A
At least 50switching operations
Maximum switching current 35 A
Maximum switching voltage 800 V
Maximum power 12 kW
Degree of protection when plugged in IP65
Degree of protection when unplugged IP21
Fuses for ElectronicSolarSwitch F200, 600 V/4 A, fast acting and
F201, 600V/ 4A, fast acting (soldered, not
replaceable)
11.8 Data Storage Capacity
Energy yields in the course of the day 63days
Daily yields 30 years
Event messages for users 250 events
Event messages for installers 250 events