SB3000TL-21 SB3600TL-21
Maximum output current 16A 16A
Total harmonic distortion of the output current
with total harmonic distortion of the AC voltage
<2%, and AC power >50% of the rated power
≤4% ≤4%
Inrush current < 20% of the nominal
AC current for a
maximum of 10ms
< 20% of the nominal
AC current for a
maximum of 10ms
Maximum output current under fault conditions 34A 34A
Rated power frequency 50Hz 50Hz
AC power frequency* 50Hz / 60Hz 50Hz / 60Hz
Operating range at AC power frequency 50Hz 45Hz to 55Hz 45Hz to 55Hz
Operating range at AC power frequency 60Hz 55Hz to 65Hz 55Hz to 65Hz
Power factor at rated power 1 1
Displacement power factor cosφ, adjustable
0.8underexcited to 1
to 0.8overexcited
0.8underexcited to 1
to 0.8overexcited
Feed-in phases 1 1
Connection phases 1 1
Overvoltage category in accordance with
IEC60664-1
III III
* depending on the configured country data set
Efficiency
SB3000TL-21 SB3600TL-21
Maximum efficiency, η
max
97.0% 97.0%
European weighted efficiency, η
EU
96.0% 96.4%
11.1.2 SunnyBoy4000TL/ 5000TL
DC Input
SB4000TL-21 SB5000TL-21
Maximum DC power at cosφ=1 4,200W 5,200W
Maximum input voltage 750V 750V
MPP voltage range 175Vto500V 175Vto500V
Rated input voltage 400V 400V
Minimum input voltage 125V 125V
11 Technical Data
SMA Solar Technology AG
Operating ManualSB30-50TL-21-BE-en-1148