Climatic Conditions
As per IEC60721-3-4, installation typeC, class4K1
Extended temperature range −40°C to +45°C
Extended humidity range 0% to 100%
Extended air pressure range 79.5kPato106kPa
As per IEC60721-3-4, transport typeE, class2K3
Temperature range −25°C to +70°C
Features
Power-line communication to inverters As standard
Speedwire/Webconnect communication to
SMA communication products, RJ45
As standard
Display of the PV system and communication sta-
tus
2 LEDs
Torques
Screw terminals 0.6 Nm
Data Storage Capacity
Energy yield over the day per inverter At least 63days
Daily yields per inverter At least 30years
Event messages of the SunnyMultigate for users At least 1,024 events
Event messages of the Sunny Multigate for in-
stallers
At least 1,024 events
Event messages per inverter for users At least 256 events
Event messages per inverter for installers At least 256 events
14.4 Torques of AC Field Plugs
Screw in insulator 0.8 Nm
Screw connection of the AC plug enclosure, ini-
tial torque
3.3 Nm
Screw connection of the AC plug enclosure, end
torque
4.4 Nm
14 Technical Data
SMA Solar Technology AG
Installation Manual 71SMA-SB240-IA-en-12
Comments to this Manuals