6.7.3 Device Conflict
A device conflict occurs when a micro inverter is removed from a Sunny Multigate and connected to
a different Sunny Multigate within the same system. In this case, the old Sunny Multigate retains the
allocation of the micro inverter and the micro inverter is allocated to two Sunny Multigates. The old
allocation must be deleted in Sunny Explorer. It is not possible to transfer parameters or data.
Requirement:
You must be logged into Sunny Explorer in the user group Installer.
Procedure:
1. In the system tree, select the micro inverter to be deleted in the old Sunny Multigate.
2. Select .
3. Confirm the security prompt.
The removed micro inverter is deleted in the old Sunny Multigate and the inverter data is
deleted.
4. Restart Sunny Explorer and log in again.
In the system tree, the micro inverter is assigned to the Sunny Multigate to which it is connected.
6.8 Changing the Device Name
1. Select the relevant device in the System tree.
2. Select the tab Settings in the device menu.
3. Select the parameter group Type Label.
4. Select [Edit].
5. Enter the desired name in the field Device name. Remember that the maximum permitted
number of characters is 24.
6. Select [Save].
The new name is saved in the device.