OperatingManualSUNNYBOY1300TL/ 1600TL/ 2100TLSB13-21TL-BE-en-11 | 98-102300.01 | Version 1.1AMERICAN ENGLISH
3 Scope of DeliveryCheck the scope of delivery for completeness and any externally visible damage. Contact yourdistributor if the scope of delivery is
Position Quantity DesignationN 1 Operating manual, supplementary sheet with inverter de-fault settingsO 1 Speedwire/Webconnect interface* Optional3 Sc
4 Product Description4.1 Sunny BoyThe Sunny Boy is a transformerless PV inverter which converts the direct current of the PV array togrid-compliant al
Symbols on the Inverter and on the Type LabelSymbol ExplanationBy tapping on the enclosure lid, you can activate and operate the display(see Section9
Symbol ExplanationRisk of burns due to hot surfacesThe product can get hot during operation. Avoid contact during opera-tion. Allow the product to coo
BLUETOOTHVia BLUETOOTH, the inverter can communicate with various BLUETOOTH devices (for informationon supported SMAproducts, see www.SMA-Solar.com).
5 Mounting5.1 Requirements for MountingRequirements for the mounting location:Danger to life due to fire or explosionDespite careful construction, ele
Dimensions for mounting:Figure 3: Position of the anchoring pointsRecommended clearances:If you maintain the recommended clearances, adequate heat dis
Figure 4: Recommended clearancesPermitted and prohibited mounting positions:☐ The inverter must be mounted in one of the permitted positions. This wil
5.2 Mounting the InverterAdditionally required mounting material (not included in the scope of delivery):☐ Two screws that are suitable for the suppor
Legal ProvisionsThe information contained in these documents is property of SMA Solar Technology AG. Anypublication, whether in whole or in part, requ
8. If no additional grounding or equipotentialbonding is required, secure the inverter to thewall mounting bracket with the M6x12 screw toprevent it f
6 Electrical Connection6.1 Safety during Electrical ConnectionDanger to life due to high voltages of the PV arrayWhen exposed to sunlight, the PV arra
6.2 Overview of the Connection Area6.2.1 View from BelowFigure 6: Connection areas and enclosure openings at the bottom of the inverterPosition Design
6.2.2 Interior ViewFigure 7: Connection areas in the interior of the inverterPosition DesignationA Slot and connection area for an SMA communication i
☐ Insulation stripping length: 4mm☐ The cable must be dimensioned in accordance with the local and national directives for thedimensioning of cables.
Safety in accordance with IEC62109 when the grounding conductor monitoring isdeactivatedIn order to guarantee safety in accordance with IEC62109 whe
Requirements:☐ The connection requirements of the grid operator must be met.☐ The grid voltage must be in the permissible range. The exact operating r
• Insert N (or respectively L2 in case of split phase) into screw terminal1 on the bush insertand tighten the screw.• Insert L (or respectively L1 in
Additionally required material (not included in the scope of delivery):☐ Ring terminal lug M6☐ 1 grounding cableCable requirement:☐ Grounding cable cr
Connection plan:Figure 9: Circuit diagram with multiple inverters for connection to an operation indicator and circuit diagram forconnection to a faul
Table of Contents1 Information on this Document ... 51.1 Validity...
Overview of the connection area:Figure 10: Fault indicator relay inside the inverterPosition DesignationA Terminals of the fault indicator relayB Cabl
Procedure:1.Danger to life due to electric shock• Ensure that the inverter is disconnected from all voltage sources (see Section10"Disconnecting
☐ The thresholds for the input voltage and the input current of the inverter must be adhered to(see Section11 "Technical Data", page48).☐
5. Check whether the DC connectors have the correct polarity.If the DC connector is equipped with a DC cable of the wrong polarity, the DC connector m
8.Damage to the inverter due to moisture ingressThe inverter is only properly sealed when all unused DC inputs are closed with DC connectorsand sealin
7 Commissioning7.1 Commissioning ProcedureProcedure See1. Connect to the communication interface. Installation manual of the com-munication interface2
2. Remove all screws from the enclosure lid and pull the enclosure lid forward smoothly.3. Remove the grounding conductor from the bottom of the enclo
Self-test in accordance with CEI0-21 during commissioning (applies to Italy only)The Italian standard prescribes that an inverter can only operate on
The self-test changes the upper and lower disconnection values for each protective function on alinear basis for frequency monitoring and voltage moni
7.4.2 Restarting the Self-Test1. Disconnect the circuit breaker and secure it against reconnection.2. If the fault indicator relay is used, switch off
7.1 Commissioning Procedure ... 357.2 Changing the Display Language ...
8 Configuration8.1 Configuration ProcedureOnce you have commissioned the inverter, you may have to adjust various settings via acommunication product.
☐ A communication product corresponding to the type of communication used must beavailable.☐ The inverter must be registered in the communication prod
The country data set must be set correctly.If you select a country data set which is not valid for your country and purpose, it can cause adisturbance
9 Operation9.1 Display Messages9.1.1 Measuring ChannelsMeasuring channels are measured values shown on the display. Additionally, you can read outfurt
Message ExplanationGrid mon. Grid monitoring. This message appears before the inverter is connected to theutility grid, if irradiation is low, and fol
9.3 Activating and Operating the DisplayYou can activate and operate the display by tapping on the enclosure lid.Procedure:1. Activate the display. Ta
10 Disconnecting the Inverter from Voltage SourcesPrior to performing any work on the inverter, always disconnect it from all voltage sources asdescri
11.Damage to the inverter due to electrostatic dischargeTouching electronic components can cause damage to or destroy the inverter throughelectrostati
11 Technical DataDC InputSB1300TL-10 SB1600TL-10 SB2100TLMaximum DC power at cosφ=1 1,400W 1,700V 2,200WMaximum input voltage 600V 600V 600
SB1300TL-10 SB1600TL-10 SB2100TLTotal harmonic distortion of the outputcurrent with total harmonic distortionof the AC voltage <2%, and ACpower
1 Information on this Document1.1 ValidityThis document is valid for the following device types from firmware version4.50:• SunnyBoy1300TL (SB1300
Power loss in night mode 0.1WTopology transformerlessCooling method ConvectionDegree of protection in accordance withIEC60529IP65Protection class in
Transport in accordance withIEC60721-3-2, Class2K3Extended temperature range −25°Cto+70°CFeaturesDC Connection SUNCLIX DC connectorAC connection
Cylindrical screw for attaching the enclosure tothe wall mounting bracket6.0NmSUNCLIX swivel nut 2.0NmCommunication interface connection 1.5Nm11 Te
12 AccessoriesYou will find the accessories for your product in the following overview. If required, these can beordered from SMASolarTechnologyAG
13 ContactIf you have technical problems with our products, contact the SMAServiceLine. We need thefollowing information in order to provide you wit
France SMA France S.A.S.LyonMedium Power SolutionsOnduleurs : +33472090440Communication : +33472090441Hybrid Energy SolutionsSunny Island : +3
SMA Solar (Thailand) Co., Ltd. +6626706999대한민국 SMA Technology Korea Co., Ltd.서울+82-2-520-2666+9712234-6177 SMA Middle East LLC鲵뼑ꖱ霢끭Ё࣫Ҁ/01,2349:
14 EC Declaration of Conformitywithin the meaning of the EC directives• 2004/108/EG (Electromagnetic compatibility, EMC)• 2006/95/EG (Low voltage dire
SMA Solar Technologywww.SMA-Solar.com
Document title and content Document type"Leading Leakage Currents"Information on the Design of Transformerless InvertersTechnical Informatio
2 Safety2.1 Intended UseThe Sunny Boy is a transformerless PV inverter which converts the direct current of the PV array togrid-compliant alternating
Danger to life due to high voltages of the PV arrayWhen exposed to sunlight, the PV array generates dangerous DC voltage which is present in theDC con
Dust and water intrusion can damage the inverter.If the inverter is equipped with an ESS, the inverter complies with degree of protection IP65 whenthe