Sma METER CONNECTION BOX User Manual Page 23

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 22
SMA Solar Technology AG Parameter Overview
Installation Guide METERBOX-IEN110611 23
11.2 Adjustable Parameters
The adjustable parameters are displayed on the computer using the Sunny WebBox. The adjustable
parameters can be changed on the user interface of the Sunny WebBox.
Name Description Value/Range Explanation Default
value
DevNam Name of the Meter
Connection Box
You can enter up to 32
characters. The following
characters can be used:
A-Z a-z 0-9 _ - + * #
(space). Unknown characters
are replaced by spaces.
DevRs
*
*
This parameter is only visible when you are logged on to the Sunny WebBox as "Installer". To do this, follow the Sunny WebBox
manual.
Restart
Restarts the Meter
Connection Box
0Restart off0
> 0 The unit is being
restarted
DeviceType Selects the energy meter type PV-Generation PV yield meter is
selected
GridFeed-In PV feed-in meter is
selected
GridConsumption Grid consumption
meter is selected
SmaNetBd
**
**
This parameter is only visible and adjustable when you are logged on to the Sunny WebBox in Service mode.
Sets the baud rate 1 200 1 200 baud
S0 Edge
*
Evaluates the energy meter's
signal
Rising Edge Rising edge is
evaluated
Falling Edge Falling edge is
evaluated
S0 Impuls/
kWh
Number of energy meter
pulses per kWh
S0 Offset Meter reading of the energy
meter
The Meter Connection Box's
meter reading must be
adjusted to the meter reading
of the energy meter. You must
enter product of the meter
reading multiplied by 100
(e.g. to obtain 10.25 kWh,
you must enter 1 025).
0