Sunny Boy Control SMA Technologie AG
User Manual SUNBC-14:NE0206 145
10 Technical Data and Settings
10.1 Technical Data
Hardware
Operating voltage: 110 – 120 V, 50 – 60 Hz (for UL devices)
110 – 240 V, 50 – 60 Hz (for all versions other than
UL)
Power consumption: During operation:
4 – 6 W (Sunny Boy Control)
9 – 11 W (Sunny Boy Control Plus)
(depending on the number
of Sunny Boys connected)
In stand-by mode:
3 W (Sunny Boy Control)
8 W (Sunny Boy Control Plus)
Carrier frequency for
Powerline communication: 132.45 kHz
Transmission protocol: DIN EN 50065 part 1 (VDE 0808 part 1)
Operating temperature: -13 – 122 °F (-25 – 50 °C)
Measurements: 234 x 127 x 68 mm / 9.2 x 5 x 2.7 in.
(Sunny Boy Control)
234 x 127 x 88 mm / 9.2 x 5 x 3.5 in.
(Sunny Boy Control Plus)
Display: 4 x 16 characters
Weight: 1,400 g / 49.4 oz. (Sunny Boy Control)
1,750 g / 61.7 oz. (Sunny Boy Control Plus)
Protection: IP40
Fuse: automatic overload protection, 365 V / 90 mA